Tools
Free tools
Five free, brand-neutral tools. The math is shown on each page so you can check it against your own appliance labels.
Generator size calculator
Pick the appliances you need during an outage. We add running watts, then the single largest starting surge, and show the size class that fits.
Open the tool →RV amp calculator
Check whether your RV loads fit a 30-amp or 50-amp service and how many generator watts you need to feed it.
Open the tool →Fuel run-time estimator
Use your generator’s own spec-sheet numbers to estimate hours per tank and fuel for a multi-day outage.
Open the tool →Watts, amps and volts converter
Turn a nameplate amp rating into watts (or back), with an optional power factor for motors.
Open the tool →Outage prep checklist
A tick-off checklist for before, during, and after a power outage. It saves in your browser.
Open the tool →How our tools work
Each calculator shows its formula. Appliance wattages are editable defaults taken from the upper end of published ranges, so results lean toward enough power rather than too little. Your appliance’s nameplate always wins over our defaults.
Start with the generator size calculator. Tick only what must run at the same time, replace our default wattages with the numbers on your appliance labels, and note two results: the running total with headroom and the peak when the biggest motor starts. Those are the two numbers to compare against any generator's running and starting ratings.
If a label lists amps instead of watts, use the converter first. If you are planning for an RV, the RV amp calculator checks your loads against the 30-amp or 50-amp limit. Once you know roughly what size generator you have or want, the fuel run-time estimator uses its spec-sheet run time to plan fuel for a multi-day outage, and the checklist covers the safety steps that matter most: outdoor placement, carbon monoxide alarms, and never backfeeding a house outlet.
Nothing you type into a tool is saved on our servers unless the tool says so. The calculators and the outage checklist run entirely in your browser.
Match the tool to the question
These five tools answer different questions. Using the wrong one is how a sizing estimate goes sideways.
Use the generator size calculator when you need to know whether a set of household loads can run at the same time. It totals running watts, then adds the extra starting demand of only the single largest motor. That peak is what a generator’s starting rating has to cover. The editable defaults are the high end of published ranges: Champion Power Equipment’s generator wattage chart, plus a few household items from Virginia Cooperative Extension publication BSE-301. The nameplate on the appliance replaces any default. When a label lists amps and volts instead of watts, run those through the watts, amps and volts converter first and carry the watt figure into the size calculator.
Use the RV amp calculator for a camper hookup. It checks the load list against a 30-amp or 50-amp shore service and shows how many generator watts that inlet needs when there is no pedestal. It is not a substitute for the house calculator, and the house calculator is not a substitute for it.
Use the fuel run-time estimator after you know the generator you are considering. It does not assume a gallons-per-hour rate. You enter the run time and tank size printed on that model’s spec sheet, then the hours per day you plan to run it. Read FEMA’s Ready.gov power-outage page alongside the result, because how long you run the unit is also a placement and fuel-storage decision.
Use the outage prep checklist once the numbers are settled. It is a tick list for outdoor placement, carbon monoxide alarms, and connecting through a transfer switch or interlock rather than a cord into a wall outlet. The Consumer Product Safety Commission and the CDC both treat generator exhaust as a carbon monoxide hazard and tell people to run portable generators outside, away from windows, doors, and vents. The carbon monoxide safety guide links those agency pages in full.