Generator carbon monoxide safety: where to put it and why
Last updated
How far a generator must be from your house, why garages are never safe, CO alarm placement, and the symptoms to act on.
At heart, a portable generator is a small gasoline engine, and its exhaust contains carbon monoxide (CO), a gas no one can see or smell. Federal safety agencies do not soften the risk. The U.S. Consumer Product Safety Commission warns that the CO from a portable generator can kill you in minutes. Many generator deaths happen during storms and in the days right after them, when people run generators in garages, in basements, or too close to the house.
The placement rules
Outside only. Never run a generator inside a home, garage, basement, crawl space, shed, or enclosed porch, even with the doors and windows open. Fans and open garage doors do not clear CO quickly enough to keep anyone safe.
Far from openings. The CDC advises keeping a generator more than 20 feet from any window, door, or vent. NFPA says to place it outdoors, well away from doors, windows, and vents that could let CO come indoors. Farther is better. Aim the exhaust away from the house and away from the neighbors’ homes too.
Watch the wind. Even a generator placed outside can push exhaust indoors if it sits upwind of an open window. Close the windows on the side of the house nearest the generator.
Keep it dry, but not enclosed. Rain is one of the most common reasons people move a generator into the garage. Use an open, canopy-style cover or tent designed for running generators instead, and keep the unit on a dry, level surface; Ready.gov notes a wet generator can cause electric shock. Never fully enclose a running generator.
CO alarms are not optional
Install battery-operated CO alarms, or plug-in alarms with battery backup, on every level of the home and outside the sleeping areas. Test them before storm season starts. Because CO has no smell, an alarm is the only warning anyone will get. Ready.gov lists CO alarms as a core part of outage preparation.
CO shutoff features
Many newer portable generators include a sensor that shuts the engine off when CO builds up around it, designed to voluntary safety standards. Some also have lower-emission engines. These features help, but they do not make it acceptable to run a generator in a garage. Follow the placement rules whatever features the generator has.
Other generator hazards
- Backfeeding. Never plug a generator into a household outlet. Power can flow back into the utility lines and injure line workers or neighbors. Use a transfer switch or interlock installed to code instead. See transfer switch vs interlock.
- Refueling. Turn the generator off and let it cool before adding fuel, because gasoline spilled on a hot engine can ignite.
- Shock. Keep hands dry, do not run a generator in standing water, and use outdoor-rated cords that are in good condition.
A one-minute checklist
- Generator outside, more than 20 feet from openings, with the exhaust pointed away.
- CO alarms working on every level.
- Cords outdoor-rated, and no backfeeding through an outlet.
- Engine off and cool before refueling.
Print the full outage prep checklist and keep it with the generator so it is on hand when needed.
How serious the risk is
The CDC describes carbon monoxide as an odorless, colorless gas that "kills without warning." It reports that each year more than 400 Americans die from unintentional CO poisoning not linked to fires, more than 100,000 visit an emergency department, and more than 14,000 are hospitalized. Portable generators are one of the household sources the CDC names specifically. Many generator-related poisonings happen during and after storms, when people are tired and stressed and are running equipment in ways they are not used to.
Who is most at risk
The CDC says everyone is at risk, but infants, older adults, and people with chronic heart disease, anemia, or breathing problems are more likely to get sick. People who are asleep or intoxicated can die before they notice any symptoms. That is why a CO alarm, rather than anyone's senses, is the real safeguard.
Where to put the generator, specifically
The CDC's guidance is to use generators only outside, more than 20 feet from any windows, doors, and vents. Ready.gov gives the same distance and adds attached garages to the list. In practice:
- Never in a garage, even with the door open. CO can build up quickly and seep into the house.
- Never on a porch or under a carport against the house, and never in a crawl space or basement.
- Point the exhaust away from the house and from the neighbors' homes.
- Check the wind. Exhaust can drift toward windows on the downwind side.
- Mind the neighbors. In dense neighborhoods, one generator's exhaust can reach the house next door. It is worth talking with neighbors about placement.
CO alarms: placement and maintenance
The CDC recommends battery-operated or battery-backup CO detectors near every sleeping area. Ready.gov recommends them on every level of the home. The CDC also advises:
- Check the batteries twice a year, for example when the clocks change.
- Replace the detector according to the manufacturer's instructions, or every five years.
- Consider a model with a digital readout, which can show the highest CO level it has recorded.
During an outage, a plug-in alarm without battery backup will not work, so make sure every alarm has batteries.
Know the symptoms and act fast
The CDC lists headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion as the most common symptoms. They are often described as "flu-like." If several people or pets in the home feel sick at the same time, especially while a generator or other fuel-burning device is running, suspect CO.
If CO poisoning is suspected or an alarm sounds:
- Get everyone, pets included, outside into fresh air immediately.
- Call 911 or the local emergency number.
- Do not go back inside until emergency responders say it is safe.
- Turn off the generator only if that can be done without going back into a contaminated area.
Report generator poisonings
The CDC encourages anyone who has had a poisoning incident involving any generator to report it to the U.S. Consumer Product Safety Commission. Those reports help regulators track dangerous products and patterns.
For the agency figures in one place, see portable generator carbon monoxide: the federal numbers.
Measure to the opening, then to the neighbor’s opening
People measure generator distance to the wall they can see and stop. The openings are what matter. A basement hopper window, a dryer vent, an attic vent, and a door you prop open because the cord comes through it are all paths into the house. The CDC’s wording is more than 20 feet from windows, doors, and vents. Ready.gov adds attached garages and includes the fuel in the outdoor rule. The CPSC alert tells you to point the exhaust away from the home and from any other building a person could enter. On a narrow lot, the second half of that sentence is the neighbor’s door, not an extra courtesy.
A carbon monoxide shutoff on the generator is a last device, not a placement strategy. It may trip after levels are already high near the machine, and it does nothing for a house whose alarm batteries were removed. Test the indoor alarms on the schedule the maker printed, and replace the units when they pass the date. Symptoms in people, headache, nausea, dizziness, confusion, are the signal to get everyone into fresh air and to call for help, not to “air the room out and go back to sleep” with the generator still running where it was.
Do not revise placement to solve weather. Rain, snow, and a desire to keep the machine from being stolen all push generators into garages, onto porches, and under eaves. Those are the locations the alerts forbid even with the door open. If the only dry spot is too close to an opening, the safe choice is not to run it, or to run it farther away on a heavier cord, not to slide it closer. Report a poisoning to the people the CPSC and local health authorities ask you to tell; a near miss that never gets counted stays invisible in the next year’s statistics.
Free worksheet · PDF
Generator Sizing Worksheet
A printable worksheet to add up running and starting watts, pick the right size, and set up your generator safely.
- Fill-in table for running and starting watts
- The simple math for picking a size
- Carbon monoxide and safe-placement checklist
Free. We email you the download link, plus an occasional plain-English guide. Unsubscribe any time. We never sell your email. Privacy