How to read a generator spec sheet

Last updated

What running watts, starting watts, THD, run time, outlets, decibels and EPA/CARB labels actually mean on a generator listing.

Generator listings pack a great deal of information into a few lines. Here is what each common spec means and which ones are worth comparing first.

Running watts (rated watts)

This is the power the generator can supply continuously, and it is the most important number on the sheet. Compare it with the running total plus headroom from the calculator.

Starting watts (peak or surge watts)

This is the power the generator can supply for a brief moment to start motors. It is always higher than running watts, and on many boxes it is the number printed biggest. It has to cover the running total plus the largest motor surge.

Fuel type and dual-fuel ratings

Dual-fuel generators run on either gasoline or propane. Their running and starting ratings are usually lower on propane, and spec sheets list both. Compare the rating for the fuel that will actually be used.

Run time

Run time is usually given as hours on a full tank at a stated load, for example 25% or 50%. A figure at 25% load looks longer than one at 50%, so compare like with like. Our fuel run-time estimator converts it to the real load.

Outlets

  • 5-20R: standard household duplex outlets (120 V).
  • TT-30R: 30-amp RV outlet (120 V).
  • L5-30R: 30-amp twist-lock (120 V).
  • L14-30R: 30-amp twist-lock with 120/240 V, common for transfer switch inlets.
  • 14-50R: 50-amp RV outlet (120/240 V).

Feeding a transfer switch or powering 240 V loads requires an L14-30R or a larger 240 V outlet.

THD (total harmonic distortion)

THD measures how closely the output matches a clean sine wave. Lower is cleaner. Inverter generators often advertise low THD, and some conventional generators list it as well. If the equipment to be powered calls for clean power, compare this figure.

Noise (dB)

Decibel ratings are usually measured at a specific distance (often 7 meters or 23 feet) and load (often 25%). Because decibels are logarithmic, a difference of a few dB is noticeable. Compare only figures measured the same way.

What to compare first

  1. Running watts against actual needs.
  2. Starting watts against the peak.
  3. Voltage and outlets for the hookup.
  4. Run time at the same load.
  5. Noise, if neighbors or campgrounds are a concern.

A sample spec sheet, decoded

Here is a hypothetical spec sheet for a mid-size dual-fuel portable generator (not a specific model), with what each line means:

  • Starting watts: 9,500 (gas) / 8,500 (propane). The peak output the generator can supply for a few seconds to start motors.
  • Running watts: 7,500 (gas) / 6,750 (propane). The output it can sustain. The propane figure is lower because propane holds less energy per gallon than gasoline. EIA lists about 91,452 Btu per gallon for propane versus about 120,214 for gasoline.
  • Fuel tank: 6.6 gallons.
  • Run time: 10 hours at 50% load (gas). This can be used to estimate gallons per hour: about 0.66.
  • Outlets: 2 × 120 V 20 A duplex (5-20R), 1 × 120/240 V 30 A locking (L14-30R). The L14-30R is the outlet used with a transfer switch or interlock inlet.
  • Noise: 74 dB(A) at 23 feet. Note the distance, and the load if one is stated.
  • THD: under 23%. Lower THD means cleaner power; this hypothetical figure is typical of a conventional (non-inverter) unit.
  • Engine: 420 cc OHV.
  • CO shutoff: yes.

Ratings to treat with caution

  • "Peak" or "max" watts in big print. Some marketing puts the starting number front and center. Always size on running watts.
  • Run time at 25% load. Real household loads are often higher. Use the 50% figure when both are published.
  • Noise at a quarter load. Compare noise ratings only at the same distance and load.
  • "Up to" claims on runtime or fuel efficiency.

Inverter-specific terms

Inverter generators often list:

  • Eco or economy mode, which lowers engine speed at light load to save fuel and cut noise. It can slow the response when a large motor starts, so it may need to be turned off for refrigerators or AC units.
  • Parallel capability, which lets two compatible units be linked for more output with a parallel kit.
  • Clean power / low THD, typically under 3%. That is the preferred choice for sensitive electronics.

Safety and compliance labels

  • CO safety shutoff. Many generators now include a sensor that shuts the engine down if carbon monoxide builds up around the unit. It is a valuable backup, but it does not replace operating outdoors. Ready.gov's 20-foot guidance still applies; see carbon monoxide safety.
  • Emissions certification. Look for EPA certification, and for CARB compliance when the generator will be used in California.
  • Listing marks from a recognized testing laboratory.

Comparing two generators side by side

Once there is a shortlist, put these in a table:

  1. Running watts on the fuel that will be used.
  2. Starting watts.
  3. Run time at 50% load, and tank size.
  4. Outlet types: does it have the needed 240-volt locking outlet?
  5. Noise at the same distance and load.
  6. THD, if it will power electronics.
  7. Weight and wheels.
  8. Warranty length and service network.

Running watts and outlet type usually settle the decision, and the rest helps choose between finalists. Use our calculator to total the loads first, then shop for a generator whose running watts on the chosen fuel exceed that total with headroom.

Keep the manual

After buying, keep the owner's manual with the generator, or save the PDF on a phone. It holds the real numbers needed later: oil capacity and grade, spark plug type, maintenance intervals, altitude derating, and the wiring diagram for each outlet.

What the sheet is measured against

A spec sheet is a set of test conditions, not a promise about your outage. The running-watt rating is the continuous number worth comparing with the calculator. The larger surge figure is a brief capability, and it is often the number printed in the biggest type because it looks better on a shelf. If you only remember one habit, match your simultaneous running load to the running rating, then check that the surge rating covers the single largest motor on top of that running load. Adding every appliance’s surge together double-counts a moment that rarely happens.

Run time is the line people misread most often. Manufacturers commonly publish hours at a quarter or half of rated load, on a full tank, in mild conditions. A refrigerator, a few lights, and a router may sit near that fraction. A window air conditioner plus a microwave will not. Divide tank size by the published hours and you get a gallons-per-hour figure that only applies at the load they tested. Heavier use burns more. Heat, altitude, and an old air filter can cut output before the tank is the thing that stops you. The EIA’s Btu page is useful here only as a reminder that propane and gasoline are not equal volumes of energy; the generator’s own propane and gasoline ratings, printed separately on a dual-fuel sheet, are the numbers to compare.

Outlets are a wiring fact, not a wattage fact. A sheet that lists a 120-volt duplex and a 120/240-volt twist-lock is telling you which cords and which inlet the unit can feed. A 240-volt well pump or a transfer-switch inlet needs that twist-lock (or the equivalent the electrician specified). An inverter under a few thousand watts is often 120 volts only, even when the wattage looks large enough on paper. THD, the total harmonic distortion figure, matters when the sheet is being asked to run electronics or a furnace board. A conventional generator may omit THD or list a high number. An inverter sheet often advertises a low one. Neither figure makes exhaust safe to breathe.

Noise ratings are usually a decibel number at a stated distance, often about 23 feet, at a stated load. A quieter number at a longer distance is not a better generator; it is a different test. Compare sheets that use the same distance and a similar load, or treat the comparison as rough. EPA and CARB labels, when they appear, are about emissions compliance for sale in certain places. They do not authorize indoor use. The CPSC alert still requires outdoor operation, far from openings, regardless of which emissions sticker is on the fuel tank.

When two sheets look close, write four lines for each: running watts on the fuel you will actually burn, surge watts, hours at the published load, and whether a 240-volt outlet exists. Ignore the marketing name. If the manual you download later disagrees with the web listing, the manual is the one that shipped with that serial number.

Free worksheet · PDF

Generator Sizing Worksheet

A printable worksheet to add up running and starting watts, pick the right size, and set up your generator safely.

  • Fill-in table for running and starting watts
  • The simple math for picking a size
  • Carbon monoxide and safe-placement checklist