There is no single right size, because the answer depends on what you decide to keep running. The useful question is not “what size generator for a 2,000-square-foot house?” but “which loads do I need during an outage, and can I take turns with the rest?”
Step 1: Decide your tier
Most households fall into one of three tiers.
Essentials. Refrigerator, a freezer, a few lights, phone and internet, a furnace fan in winter, and a sump or well pump if you have one. This is what most people mean when they say they want to “get through” an outage.
Comfort. Essentials plus a window air conditioner or two, a microwave, a TV, and a washing machine used in turns.
Whole house. Central air conditioning, an electric water heater, an electric range or dryer, all at once, with no juggling. This is usually a permanently installed standby generator.
Step 2: Add up running watts
Using published manufacturer ranges (Champion’s chart, high end), an essentials list might look like this:
| Load | Running watts | Starting watts |
|---|---|---|
| Refrigerator | 400 | 1,200 |
| Freezer | 500 | 1,000 |
| Furnace fan (1/2 HP) | 800 | 1,600 |
| Sump pump (1/2 HP) | 1,050 | 2,150 |
| LED lights (10 bulbs) | 150 | none |
| Modem, router, chargers | 120 | none |
| Total running | 3,020 |
The largest extra starting demand is the sump pump (2,150 − 1,050 = 1,100 W), so the peak is about 4,120 W.
Step 3: Add headroom
Running an engine at 100% for hours is hard on it, and you will forget something. Dividing the running total by 0.8 leaves about 20% spare: 3,020 ÷ 0.8 ≈ 3,800 running watts. That points to a portable generator in roughly the 4,000 to 5,000 running-watt class with a starting rating above 4,120 W.
Step 4: Check the big 240-volt loads
Four loads change the answer dramatically:
- Central air. Champion lists a 3-ton unit at 3,000 to 3,500 running watts and 5,000 to 6,000 starting.
- Electric water heater. 3,000 to 4,500 watts with no surge.
- Electric dryer. 4,000 to 6,000 watts.
- Deep well pump over 1/2 HP. Often 240 V; 1 HP is 1,000 to 2,000 running and up to 4,000 starting.
Any one of these can double the generator you need. They also need 240-volt output and a hookup that carries it, which rules out most small inverter generators. Many homeowners handle them by taking turns: heat water for an hour, then turn it off before running the dryer.
Typical size classes
These are broad market categories, not a standard:
- About 2,000 to 2,200 W (small inverter): a refrigerator plus lights and chargers, one thing at a time.
- About 3,000 to 5,000 W (portable): essentials, including one pump or furnace fan.
- About 6,000 to 10,000 W (large portable): essentials plus comfort items, often including a 240 V well pump through a transfer switch.
- About 10 to 26 kW (home standby): much or all of the house, installed permanently with an automatic transfer switch, usually running on natural gas or propane.
Why this matters more than it used to
The U.S. Energy Information Administration reported that the average U.S. electricity customer experienced about 11 hours without power in 2024, the most in the ten years it has tracked, driven largely by hurricanes. Longer outages make fuel supply and running time as important as wattage. See the fuel run-time estimator.
Do the math for your house