What size generator do I need for my house?

Last updated

A step-by-step way to size a generator for essentials, most of the house, or the whole house, with typical size classes explained.

There is no single right size, because the answer depends on what the household decides to keep running. The useful question is not “what size generator for a 2,000-square-foot house?” but “which loads do I need during an outage, and can I take turns with the rest?”

Step 1: Decide your tier

Most households fall into one of three tiers.

Essentials. Refrigerator, a freezer, a few lights, phone and internet, a furnace fan in winter, and a sump or well pump where there is one. This is what most people mean when they say they want to “get through” an outage.

Comfort. Essentials plus a window air conditioner or two, a microwave, a TV, and a washing machine used in turns.

Whole house. Central air conditioning, an electric water heater, an electric range or dryer, all at once, with no juggling. This usually means a permanently installed standby generator.

Step 2: Add up running watts

Using published manufacturer ranges (Champion’s chart, high end), an essentials list might look like this:

Load Running watts Starting watts
Refrigerator 400 1,200
Freezer 500 1,000
Furnace fan (1/2 HP) 800 1,600
Sump pump (1/2 HP) 1,050 2,150
LED lights (10 bulbs) 150 none
Modem, router, chargers 120 none
Total running 3,020

The largest extra starting demand belongs to the sump pump (2,150 − 1,050 = 1,100 W), so the peak is about 4,120 W.

Step 3: Add headroom

Running an engine at 100% for hours is hard on it, and something always gets forgotten. Dividing the running total by 0.8 leaves about 20% to spare: 3,020 ÷ 0.8 ≈ 3,800 running watts. That points to a portable generator in roughly the 4,000 to 5,000 running-watt class with a starting rating above 4,120 W.

Step 4: Check the big 240-volt loads

Four loads change the answer dramatically:

  • Central air. Champion lists a 3-ton unit at 3,000 to 3,500 running watts and 5,000 to 6,000 starting.
  • Electric water heater. 3,000 to 4,500 watts with no surge.
  • Electric dryer. 4,000 to 6,000 watts.
  • Deep well pump over 1/2 HP. Often 240 V; 1 HP is 1,000 to 2,000 running and up to 4,000 starting.

Any one of these can double the size of generator needed. They also need 240-volt output and a hookup that carries it, which rules out most small inverter generators. Many homeowners handle them by taking turns: heat water for an hour, then turn the heater off before running the dryer.

Typical size classes

These are broad market categories, not a standard:

  • About 2,000 to 2,200 W (small inverter): a refrigerator plus lights and chargers, one thing at a time.
  • About 3,000 to 5,000 W (portable): essentials, including one pump or furnace fan.
  • About 6,000 to 10,000 W (large portable): essentials plus comfort items, often including a 240 V well pump through a transfer switch.
  • About 10 to 26 kW (home standby): much or all of the house, installed permanently with an automatic transfer switch, usually running on natural gas or propane.

Why this matters more than it used to

The U.S. Energy Information Administration reported that the average U.S. electricity customer went about 11 hours without power in 2024, the most in a decade, driven largely by hurricanes. Longer outages make fuel supply and running time as important as wattage. See the fuel run-time estimator.

Do the math for your house

Use the generator size calculator with the figures from the home's own appliance labels. Then read about transfer switches and interlocks before connecting anything to household wiring.

Three example households

Example 1: Essentials only, gas furnace, city water

  • Refrigerator: 400 running / 1,200 starting
  • Furnace blower (1/2 hp): 800 running / 1,600 starting
  • Lights, router, chargers, TV: 500 running
  • Microwave (taking turns): 1,200 running
  • Running total: about 2,900 W. Largest surge on top: about 800 W (refrigerator or blower), for about 3,700 starting watts.
  • Suggested size: with 20% headroom (2,900 ÷ 0.8), about 3,600 running watts, so a generator of about 4,000 to 5,000 W, at the top of the 3,000 to 5,000 W portable class above.

Example 2: Rural home with a well pump

  • Everything in Example 1, plus a 1 hp submersible well pump at 240 V: about 2,000 running / up to 4,000 starting (the high end of Champion's 1 hp range)
  • Running total: about 4,900 W, plus the well pump's 2,000 W surge, for about 6,900 starting watts.
  • Suggested size: with 20% headroom (4,900 ÷ 0.8), about 6,100 running watts, so a generator of about 6,000 to 7,500 W, at the low end of the large-portable class above, with a 240-volt outlet and a transfer switch.

Example 3: Near-whole-house with central AC

  • Central AC (3 ton): about 3,500 running and a large starting surge (lower with a soft-start kit)
  • Refrigerator, freezer, lights, electronics, microwave, furnace blower or air handler
  • Using the high end of Champion's ranges (AC 3,500, refrigerator 400, freezer 500, lights 150, electronics 120, microwave 1,200, blower 800), about 6,700 running watts, plus the AC's 2,500 W extra starting surge. With 20% headroom that is about 8,400 running watts, the largest portables or a small home standby. At this level, many people choose a home standby generator with load management.

These numbers are illustrations. The home's own appliance labels and our calculator will give a more accurate total.

Don't forget the food clock

For anyone torn between two sizes, it helps to remember that the refrigerator does not have to run constantly. FoodSafety.gov, citing USDA, says a closed refrigerator keeps food safe for up to 4 hours, and a full freezer holds a safe temperature for about 48 hours. With a little load management, a smaller generator can protect the food while handling other loads in turns. See load management in an outage.

120 volts vs. 240 volts

Most household plug-in appliances run on 120 volts. Some major loads run on 240 volts: well pumps, central AC condensers, electric dryers, electric ranges, and some water heaters. Running any 240-volt load requires:

  • a generator with a 240-volt output (usually a four-prong locking L14-30 or a 50-amp outlet);
  • a transfer switch or interlock installed by an electrician.

When adding up loads on a transfer switch, keep the two 120-volt legs roughly balanced. Putting all the big 120-volt loads on one leg can overload that leg even when the total watts look fine.

Headroom and the 80% habit

Engines last longer and handle surges better when they are not running at their limit. A common practice is to plan for continuous loads of no more than about 80% of the generator's running rating. If the essentials total 4,000 running watts, a generator rated at 5,000 running watts or more provides that margin. Hot weather and high altitude reduce the available output, so add extra margin if either applies.

Safety and placement

Whatever size is chosen, place the generator outdoors, at least 20 feet from windows, doors, and attached garages, as Ready.gov advises. Install carbon monoxide alarms on every level of the home, and connect through a transfer switch or interlock, never by backfeeding an outlet.

A tier is a list of what you are willing to leave off

“What size generator does a house need” is not a square-footage question. Two houses with the same floor area can differ by a factor of two or more once one of them wants central air, an electric range, or a well pump on at the same time as the kitchen. The useful question is which tier you are buying: a fridge, a few lights, the modem, and a furnace blower; that list plus a sump or well pump and a window air conditioner; or something close to the whole panel, including 240-volt loads. Each tier is a different running total and a different surge. The calculator is there so the tier is a number instead of a slogan.

Write the tier down as breaker names. If the electric water heater, the dryer, and the range stay off, say so on the paper you will tape at the panel, because an interlock feeds whatever breakers you leave closed. People buy a generator for the small tier and then, on night two, turn the water heater on because the shower was cold. That single 240-volt element can exceed a generator that was honest about the small tier. Either the tier includes it, and the generator is sized for it, or the breaker stays off.

Headroom is the difference between a generator that carries the tier and one that carries it while already hot, with one extra load you forgot. The calculator’s default is a percentage, not a code requirement. Set it to zero only when you want to see the bare sum. Do not shop from the bare sum if the outage will last days. And do not shop from the surge number alone. The running rating is what the house lives on for hours. The surge rating is what it must survive for a second.

Voltage is part of the tier. A 120-volt-only inverter cannot run a 240-volt pump or a transfer inlet that expects both legs, no matter how large the watt sticker is. If the tier includes any 240-volt load, the generator and the inlet have to be 240-volt equipment, installed by someone licensed to connect them. The size class on a chart is a shopping hint after those facts, not before them.

Free worksheet · PDF

Generator Sizing Worksheet

A printable worksheet to add up running and starting watts, pick the right size, and set up your generator safely.

  • Fill-in table for running and starting watts
  • The simple math for picking a size
  • Carbon monoxide and safe-placement checklist

Free. We email you the download link, plus an occasional plain-English guide. Unsubscribe any time. We never sell your email. Privacy

Sources

  1. Champion Power Equipment, Generator Wattage Chart
  2. U.S. Energy Information Administration, Hurricanes in 2024 led to the most hours without power in 10 years
  3. FEMA Ready.gov, Power Outages
  4. FoodSafety.gov, Food Safety During a Power Outage